It's back in stock! iOKE868 Smart Metering Kit - Time to monitor your energy consumption. >>Get it now<<

RF Verification EN 13757-4 (T2-Mode)

The Wireless M-Bus standard has revolutionized smart home and smart metering. For providing interoperability between different devices it is required to be compliant with some specifications. We are happy to assist you with the RF verification of T2-Mode according to EN 13757-4. We are going to check the RF performance of the transmitter and receiver to verify the performance criteria given by the standard. This verification additionally includes tests under extreme voltage and temperature conditions which have an impact on the RF performance. We can also provide T1-Mode verification which is a subset of the T2-mode verification. Just use this T2 topic for your request and let us know about your interest in T1 only.

Remarks/Limitations: Req. Tbd

Estimated Effort (Person-Day): 6

What we need from you:

  • User Manual
  • 3/3 x DUT (for radiated / for conducted)

Our included services:
Measurments
Radiated

  • Radiated Power (TRP / EIRP, 1 frequency)
  • Radiated Sensitivity (main radiation direction)(1 frequency)

Conducted

  • Conducted output power measurement  (3 frequencies, 3 env. Temperatures)
  • Conducted Sensitivity at nominal Frequency
  • Conducted Sensitivity at min/max env Temperature
  • Conducted Sensitivity at min/max Frequency Deviation
  • Conducted Sensitivity at min/max Data Rate
  • Conducted Sensitivity at min/max Frequency
  • Conducted Blocking at center frequency +/-5%, +/- 2 MHz, +/-10 MHz
  • Conducted Selectivity at center of adjacent channels
  • Conducted Frequency Deviation on transmit (at min/typ/max env. temperature)
  • Conducted Data Rate on transmit (at min/typ/max env. temperature)
  • Preamble check
  • Postamble check

Delivery

  • Test Report
  • Telephone Call

RF Verification EN 13757-4 (S2-Mode)

The Wireless M-Bus standard has revolutionized smart home and smart metering. For providing interoperability between different devices it is required to be compliant with some specifications. We are happy to assist you with the RF verification of S2-Mode according to EN 13757-4. We are going to check the correct RF performance of the transmitter and receiver to verify the performance criteria given by the standard. This verification additionally includes tests under extreme voltage and temperature conditions which have an impact on the RF performance. We can also provide S1-Mode verification which is a subset of the S2-mode verification. Just use this S2 topic for your request and let us know about your interest in S1 only.

Remarks/Limitation: Req. Tbd

Estimated Effort (Person-Day): 6

What we need from you:

  • User Manual
  • 3/3 x DUT (for radiated / for conducted)

Our included services:
Measurement
Radiated

  • Radiated Power (TRP / EIRP, 1 frequency)
  • Radiated Sensitivity (main radiation direction)(1 frequency)

Conducted

  • Conducted output power measurement (3 frequencies, 3 env. Temperatures)
  • Conducted Sensitivity at nominal Frequency
  • Conducted Sensitivity at min/max env Temperature
  • Conducted Sensitivity at min/max Frequency Deviation
  • Conducted Sensitivity at min/max Data Rate
  • Conducted Sensitivity at min/max Frequency
  • Conducted Blocking at center frequency +/-5%, +/- 2 MHz, +/-10 MHz
  • Conducted Selectivity at center of adjacent channels
  • Conducted Frequency Deviation on transmit (at min/typ/max env. temperature)
  • Conducted Data Rate on transmit (at min/typ/max env. temperature)
  • Preamble check
  • Postamble check

 

Delivery

  • Test Report
  • Telephone Call

RF Verification EN 13757-4 (C2-Mode)

The Wireless M-Bus standard has revolutionized smart home and smart metering. For providing interoperability between different devices it is required to be compliant with some specifications. We are happy to assist you with the RF verification of C2-Mode according to EN 13757-4. We are going to check the correct RF performance of the transmitter and receiver to verify the performance criteria given by the standard. This verification additionally includes tests under extreme voltage and temperature conditions which have an impact on the RF performance. We can also provide C1-Mode verification which is a subset of the C2-mode verification. Just use this C2 topic for your request and let us know about your interest in T1 only.

Remarks/Limitation: Req. Tbd

Estimated Effort (Person-Day): 6

What we need from you: 

  • User Manual
  • 3/3 x DUT (for radiated / for conducted)

Our included services:
Radiated Measurements

  • power (TRP / EIRP, 1 frequency)
  • sensitivity (main radiation direction)(1 frequency)

Conducted Measurements

  • output power (3 frequencies, 3 environmental temperatures)
  • sensitivity at nominal frequency
  • sensitivity at min/max environmental temperature
  • sensitivity at min/max frequency deviation
  • sensitivity at min/max data rate
  • sensitivity at min/max frequency
  • blocking at center frequency +/-5%, +/- 2 MHz, +/-10 MHz
  • selectivity at center of adjacent channels
  • frequency deviation on transmit (at min/typ/max environmental temperature)
  • data rate on transmission (at min/typ/max environmental temperature)
  • preamble check
  • postamble check

Delivery

  • test report